1 METROLOGIC INSTRUMENTS, INC. Optimizer User’s Guide

Página 2

10 Application Creation An application is mainly composed of two components: Form and Menu. These are the two key elements required to create a cust

Página 3 - Table of Contents

11 Application Creation Form Number The Form number selection allows the developer to select form 1 through 10. As a feature the developer can crea

Página 4

12 Application Creation Record selection options (cont.) Save and Output Record – This selection option allows the developer to configure the Form t

Página 5 - Introduction

13 Application Creation Properties Parsing is used when the developer needs to analyze or separate the data input into more easily processed compon

Página 6

14 Application Creation Properties (Cont.) Add prefix code Setting adds a set string as a prefix to data entered in this field. Click on the checkb

Página 7 - Getting Started

15 Application Creation Min Len and Max Len The Min Len property sets the minimum length the bar code must be in order to qualify as a valid bar code

Página 8

16 Application Creation Data Type properties (Cont.) Text Any ASCII character Integer An Integer is a positive whole number (e.g. 1, 2, 3…), nega

Página 9

17 Application Creation MENU A Menu is the other key component to a well structured application program. The Menu allows the developer to subdivide

Página 10 - Application Creation

18 Application Creation Menu properties (cont.) Save Data Click on the checkbox to activate this setting. If this setting is activated it will con

Página 11

19 Application Creation LOOKUP TABLE A lookup table is a database file created for information reference. The lookup table provides data to the act

Página 13

20 Application Creation Lookup Table properties (cont.) Number of fields Setting specifies the number of fields in the lookup table. Field The pos

Página 14

21 Application Creation BAR CODE The bar code property page includes all the bar code types that are supported by the Optimus. The developer can ena

Página 15

22 Application Creation Bar code properties (cont.) Read Redundancy Read redundancy is a method by which the scanner can reliably determine that the

Página 16

23 Application Creation Bar code properties (cont.) Checksum Transmission Specifies whether the checksum characters are included in the data being t

Página 17

24 Application Creation Bar code properties (cont.) Code39 The Normal CODE 39 is a variable length bar code type that can encode the following 44 ch

Página 18

25 Application Creation Bar code properties (cont.) Enable Code 93 Click on this checkbox to enable Code 93 as an active bar code type. Enable Code

Página 19

26 Application Creation Bar code properties (cont.) Enable EAN13 ISBN / ISSN Conversion If these settings are enabled, the scanner will convert the

Página 20

27 Application Creation Bar code properties (cont.) Double Modulo 10 Enables the Optimus to scan and decode bar code that contain two Modulo 10 chec

Página 21

28 Application Creation Bar code properties (cont.) Plessey A variable length, numeric-only bar code type. Each symbol is framed by a start and a

Página 22

29 Application Creation Bar code properties (cont.) Transmit System Number The UPCE comes with 2 varieties: System Number 0 and System Number 1. Th

Página 23

Table of Contents Introduction...

Página 24

30 Application Creation Startup The Startup properties are the initial settings that will be active on the Optimus upon power up. The Startup menu

Página 25

31 Application Creation Statup Application start from This setting determines the form or menu that will be active initially on the Optimus. The ac

Página 26

32 Application Creation Settings The Settings property enables the developer to set the communication method for multiple interfaces, beep tones, da

Página 27

33 Application Creation Security The Security settings available give the developer the ability to limit certain functions. This is accomplished by

Página 28

34 Communication Communication menu allows the developer to transfer data and programs to and from the Optimus to a host device. To access the comm

Página 29

35 Communication Download Lookup Table Utilizing this option, the developer can download a customized lookup table to the Optimus, using the Download

Página 30

36 Communication Receive Data properties (cont.) File Mode This setting is the mode by which the data will be written to the file. Overwrite Allows

Página 31

37 Communication Receive Data properties (cont.) Always show this dialog box This setting must be activated in order to have the Receive Data option

Página 32

38 Contact Information and Office Locations Corporate Headquarters European, Middle East and Asian Headquarters - Singapore Metrologic Instruments

Página 33

39 Contact Information and Office Locations South America and Central America European, Middle East and Asian Headquarters - Singapore Brazil Afric

Página 34 - Communication

4 Table of Contents Italian / French Pharma code...

Página 35

5 Introduction The Optimizer software program is a rapid SW development tool designed and developed specifically for the Optimus series of portable d

Página 36

6 Introduction Common Terms Database – A collection of similar data separated into different groups to make it easy to organize and find specifi

Página 37

7 Getting Started After successful installation of the Optimizer program* on the host device activation of the program can easily be accomplished. T

Página 38

8 Getting Started The File menu contains the familiar Windows™ options such as New, Open, and Save. However, it also contains options unique to the

Página 39

9 Getting Started The Tools menu, though a familiar listing for Windows™ programs, has options completely unique to the Optimizer program. In Figur

Comentários a estes Manuais

Sem comentários