Honeywell Q539F Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
Q539An'87F
HEATING
DAMPER
MOTOR
(IF USED)
WITCH
_C
<i) I
A
■^T
-0^1
COOLING
DAMPER
MOTOR
(IF USED)
“1“
A
A X TERMINAL IS USED ON 0539 MODELS WITH FACTORY-
INSTALLED INDICATOR LED,
A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
A ISOLATING RELAY.
A VALVE OR RELAY WITH SEPARATE POWER SUPPLY MAY BE USED
IN PLACE OF OIL PRIMARY AS SHOWN BY BROKEN LINE.
FIG. 2—Q539A,B IN HEATING-COOLING APPLICA
TION WITH DAMPER MOTORS AND
ISOLATION RELAY.
Q539ATr87F
A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
A CONNECT VALVE OR RELAY TO O FOR CHANGEOVER IN COOLING
OR B FOR CHANGEOVER IN HEATING.
A X TERMINAL IS USED ON Q539 MODELS WITH FACTORY-INSTALLED
INDICATOR LED.
A RECOMMENDED HEAT ANTICIPATOR SETTING ON HEAT PUMPS IS
140% OF THE TOTAL COMBINED CURRENT DRAW OF THE FAN AND
COMPRESSOR RELAYS. STANDARD HEATING SYSTEMS CYCLE AT
5 TO 6 CPH AND HEAT PUMP SYSTEMS CYCLE AT 2.5 TO 3 CPH ON
EITHER HEATING OR COOLING. ^
FIG. 3—Q539A IN HEAT PUMP APPLICATION.
/K POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
A k valve or relay with separate power supply may BE USED
IN PLACE OF OIL PRIMARY AS SHOWN BY BROKEN LINE.
A \ THIS SUBBASEH-HERMOSTAT COMBINATION IS ALSO USED WITH
ELECTRIC HEATING COMPONENTS OR PANELS USING BOTH AC
AND DC CONTROL CIRCUITS.
FIG. 4—Q539A1147 IN HEATING-COOLING APPLICATION WITH ISOLATED CIRCUITS.
Vista de página 5
1 2 3 4 5 6 7 8 9 10 11 12

Comentários a estes Manuais

Sem comentários