Vista de página 0
K5895V2 6/03
9
9
,
,
6
6
7
7
$
$
%
%
3
3
9
9
,
,
6
6
7
7
$
$
%
%
3
3
&RPPHUFLDO%XUJODU\
3DUWLWLRQHG6HFXULW\6\VWHP
ZLWK6FKHGXOLQJ
8VHU*XLGH
ON
OFF
1
O
FF
4
M
A
X
7
I
N
S
T
A
N
T
READY
2
AW
AY
5
TEST
8
C
OD
E
0
3
S
TAY
6
B
Y
P
A
S
S
9
C
HIME
#
A
R
M
E
D
R
E
A
D
Y
1
O
F
F
4
M
A
X
7
INSTANT
READY
2
A
W
A
Y
5
T
E
S
T
8
C
O
D
E
0
3
S
T
A
Y
6
BYPASS
9
C
H
IM
E
#
A
R
M
E
D
R
E
A
D
Y
®
Vista de página 0
1 2 3 4 5 6 ... 79 80

Resumo do Conteúdo

Página 1 - &RPPHUFLDO%XUJODU\

K5895V2 6/03 99,,6677$$%%3399,,6677$$%%33&RPPHUFLDO%XUJODU\3DUWLWLRQHG6HFXULW\6\VWHPZLWK6FKHGXOLQJ 8VHU*XLGHONOFF

Página 2

– 10 – About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during y

Página 3 - TABLE OF CONTENTS

– 11 – Functions Of The Keypad 1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS#ARMEDREADY6160-00-002-V19CHIMEABCDSPEAKERLCDDISPLAYFUNCTIONKEYSLEDS

Página 4

– 12 – Functions Of The Keypad (cont’d)ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD). Displays protection point identif

Página 5 - System Overview

–13 – Functions Of The Keypad (cont’d) 9 CHIME : Turns on & off the CHIME mode. When on, any entry through a protected delay or perimeter zo

Página 6 - System Overview (cont’d)

– 14 – Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm

Página 7

– 15 – Security Codes & Authority Levels General Information At the time of installation, you were assigned an authority level and a personal fo

Página 8 - Device Timers

– 16 – Security Codes & Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. D

Página 9

– 17 – Security Codes & Authority Levels (cont’d) General Rules on Authority Levels and Changes A user may not delete or change the user code of

Página 10 - The Alpha Keypad

– 18 – Security Codes & Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function th

Página 11 - Functions Of The Keypad

– 19 – Security Codes & Authority Levels (cont’d) MULTI-ACCESS ? 0 = NO , 1 = YESIf you as a user have access to other partitions, the keypad wi

Página 12

– 2 –

Página 13

– 20 – Security Codes & Authority Levels (cont’d) PART. 1 A0* WHSE USER 003 AUTH=3G. When all partitions have been displayed, the keypad will

Página 14 - General Information

– 21 – Security Codes & Authority Levels (cont’d) To Delete a User CODE 1. Enter Master or Manager code and press the 8 key + user nu

Página 15 - Quick Arming

– 22 – Accessing Other Partitions To Access Another Partition Each keypad is assigned a default partition for display purposes, and will show only t

Página 16 - Authority Levels

– 23 – Accessing Other Partitions (cont’d) Global Arming Notes: When performing a Global Arm, if there are faults in any of the selected partitions,

Página 17 - To Exit User Edit Mode

– 24 – Accessing Other Partitions (cont’d) The following is an example of what would be displayed for a fault condition on Zone 002 (Loading Dock Wi

Página 18 - To Add a User

– 25 – Accessing Other Partitions (cont’d) Common Lobby Operation When an installation consists of a partition that is shared by users of other part

Página 19

– 26 – Accessing Other Partitions (cont’d) How User Codes Affect the Common Lobby Codes with “Global” Arming If your code is given “global arming” w

Página 20 - To Change a User's Code

– 27 – Accessing Other Panels If the user is authorized, a keypad in one panel can be used to perform system functions in other panels by using one

Página 21 - To Delete a User

– 28 – Accessing Other Panels (cont’d) Multi-Partition Multi-Panel Mode To access the multi-partition multi panel mode, perform the following steps:

Página 22 - READY

– 29 – Accessing Other Panels (cont’d) NOTES: When performing any of the arming commands, if there are faults in any of the partitions, none of the

Página 23 - Master Keypad Operation

– 3 – TABLE OF CONTENTS SYSTEM OVERVIEW ...5 General ...5 A Part

Página 24

– 30 – Accessing Other Panels (cont’d) Press 0 to exit mode. After a few seconds, the keypad displays the status of the original partition of the

Página 25 - Common Lobby Operation

– 31 – Checking For Open Zones Using the ✳ READY Key Before arming your system, all protected doors, windows and other protection zones must be clo

Página 26

– 32 – Displaying All Zone Descriptors Using the ✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in you

Página 27 - Accessing Other Panels

– 33 – Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally

Página 28

– 34 – Bypassing Protection Zones (cont’d) Quick Bypass Your system allows you to easily bypass all open (faulted) zones without having to enter zon

Página 29 - Multi-Panel View Mode

– 35 – Bypassing Protection Zones (cont’d) Group Bypass Your system allows you to easily bypass a group of zones without having to enter zone number

Página 30

– 36 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use

Página 31 - Checking For Open Zones

– 37 – Arming Perimeter Only (With Entry Delay ON) (cont’d) Auto-STAY Arming Auto-stay allows the system to automatically bypass certain zones if up

Página 32 - READY Key

– 38 – Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Important: If you are using a Symphony (Advanced User Interface), NI

Página 33 - BYPASS

– 39 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in

Página 34 - Displaying Bypassed Zones

– 4 – Arming ...43 Disarming ...43 CHIME MODE...

Página 35 - Group Bypass

– 40 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods o

Página 36 - Using the 3 STAY key

– 41 – Quick Exit Using the # + 9 Keys The Quick Exit feature allows you to exit the armed partition without having to disarm and then rearm

Página 37 - Auto-STAY Arming

– 42 – Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See

Página 38 - Using the 7 INSTANT Key

– 43 – Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light

Página 39 - Using the 2 AWAY Key

– 44 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mod

Página 40 - MAXIMUM

– 45 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their

Página 41 - Quick Exit

– 46 – Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key co

Página 42 - Memory of Alarm

– 47 – Speed Key (Macros) General Information The “A”, “B”, “C”, and/or “D” keys can be used to activate a string of commands up to 32 keystrokes

Página 43 - Disarming

– 48 – Speed Key (Macros) (cont’d) Executing To execute a Speed Key sequence, do the following: If a lettered key, A-B-C, has been assigned as a Spe

Página 44 - Using the 9 Key

– 49 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momenta

Página 45

– 5 – System Overview General Congratulations on your ownership of an ADEMCO Partitioned Security System. You've made a wise decision in choosi

Página 46 - Active Panic Functions

– 50 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by us

Página 47 - Defining

– 51 – Using Schedules Delaying the Closing Time Your system's programmed schedules may automatically arm the system at a predetermined time. I

Página 48 - Executing

– 52 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary sc

Página 49 - Access Door Control

– 53 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the te

Página 50 - Using #70 Relay Menu Mode

– 54 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which t

Página 51 - Using Schedules

– 55 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the d

Página 52 - Using Schedules (cont’d)

– 56 – Programming Device Timers (cont’d) Randomize Output Device Times Devices in your system may be set for a random schedule, whereby they will t

Página 53

– 57 – Using #77 Instant Activation Mode The #77 Instant Activation Mode is used to activate outputs, bypass zones, etc. immediately upon exiting th

Página 54 - See your installer for

– 58 – Using #77 Instant Activation Mode (cont’d) Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for

Página 55

– 59 – Using #77 Instant Activation Mode (cont’d) Additional Commands Action Code Action Specifier 77 Access Point Group Enable Group # 78 Access

Página 56

– 6 – System Overview (cont’d) A Partitioned System Simply stated, a partitioned system shares one physical alarm system among different users, each

Página 57

– 60 – Event Log Procedures General Information The system has the ability to record various events in a history log wherein each event is recorded

Página 58

– 61 – Event Logging Procedures (continued) ALARM EVENT LOG Displays time and date for zones that have either caused an alarm or have been restored

Página 59

– 62 – Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protecti

Página 60 - Event Log Procedures

– 63 – Fire Alarm System Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency,

Página 61 - 1=YES 0=NO 0

– 64 – Trouble Conditions Typical Trouble Displays The word CHECK or TRBL on the Keypad's display, accompanied by a rapid "beeping" a

Página 62 - (To Be Conducted Weekly)

– 65 – Trouble Conditions (cont’d) A display of "SYSTEM LO BAT", accompanied by a once per minute "beeping" at the Keypad indic

Página 63 - Fire Display Lock

– 66 – Recommendations For Proper Protection The following recommendations for the location of fire and burglary detection devices help provide prop

Página 64 - Typical Trouble Displays

– 67 – Recommendations For Proper Protection (cont’d) In addition, we recommend the following: Install a smoke detector inside every bedroom where a

Página 65 - Power Failure

– 68 – Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the Natio

Página 66

– 69 – Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possib

Página 67

– 7 – System Overview (cont’d) Burglary Protection The burglary protection portion of your system must be turned on or "armed" before it w

Página 68 - Emergency Evacuation

– 70 – Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing a

Página 69 - Maintaining Your System

– 71 – Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display All

Página 70 - Routine Care

– 72 – Quick Guide To System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manager code. Press CODE [8]. Enter user no.

Página 71

– 73 – Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIREis dis

Página 72

– 74 – UL NOTICE: This is a “GRADE A” system. “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT” This equipment has been tested to FCC req

Página 73 - (Alpha Display Keypads)

– 75 – “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this e

Página 74

– 76 – CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment

Página 75

– 77 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protect

Página 76

– 78 – Index #70 command... 50 4285 or 4286 VIP module ... 9, 50 AC Loss ...

Página 77 - WARNING!

– 79 – Maximum ... 7, 22 MAXIMUM...14 MAXIMUM mode.

Página 78

– 8 – System Overview (cont’d) Speed Key (Macros) The system can store a string of up to 32 keystrokes, which can be activated anytime by simply pre

Página 79

¬.9_l K5895V2 6/03 ONE YEAR LIMITED WARRANTY Honeywell International Inc., acting through its ADEMCO business ("Seller"), 165 Eileen

Página 80 - ¬.9_l

– 9 – System Overview (cont’d) Master Keypad Operation A "Master" keypad is one on which the status of all 8 partitions is displayed simul

Comentários a estes Manuais