Página 1 - 4600rp, 4600g/4600r, 4800i

™ 4600rp, 4600g/4600r, 4800iCommercial/Retail/Industrial Area ImagerUser’s Guide

Página 2 - Product Agency Compliance

ivChapter 5 - Data FormattingData Format Editor Introduction...5-1To Add a Data Format ...

Página 3 - Industry Canada ICES-003

7 - 6When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not tr

Página 4 - Australia/NZ

7 - 7Code 32 Pharmaceutical (PARAF)Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known

Página 5 - International

7 - 8Character pairs /M and /N decode as a minus sign and period respectively.Character pairs /P through /Y decode as 0 through 9.Code 39 Code PageCod

Página 6

7 - 9When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 barcodes printed with a check digit, but will not

Página 7 - Table of Contents

7 - 10Code 93< Default All Code 93 Settings >Code 93Code 93 Message LengthScan the barcodes below to change the message length. Refer to Messag

Página 8 - Chapter 3 - Output

7 - 11Straight 2 of 5 Industrial<Default All Straight 2 of 5 Industrial Settings>Straight 2 of 5 IndustrialStraight 2 of 5 Industrial Message Le

Página 9 - Chapter 4 - Data Editing

7 - 12Straight 2 of 5 IATA (Two-Bar Start/Stop)<Default All Straight 2 of 5 IATA Settings>Straight 2 of 5 IATAStraight 2 of 5 IATA Message Lengt

Página 10 - Chapter 7 - Symbologies

7 - 13Matrix 2 of 5<Default All Matrix 2 of 5 Settings>Matrix 2 of 5Matrix 2 of 5 Message LengthScan the barcodes below to change the message le

Página 11

7 - 14Code 11Check Digits RequiredThis option sets whether 1 or 2 check digits are required with Code 11 bar-codes. Default = Two Check Digits.Code 1

Página 12 - Chapter 9 - OCR Programming

7 - 15Code 128<Default All Code 128 Settings>Code 128ISBT 128 ConcatenationIn 1994 the International Society of Blood Transfusion (ISBT) ratifie

Página 13 - Chapter 11 - Utilities

vInterleaved 2 of 5 ... 7-8Code 93 ...

Página 14 - Chapter 14 - Maintenance

7 - 16Code 128 Message LengthScan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional info

Página 15 - Programming Chart

7 - 17Telepen<Default All Telepen Settings>TelepenTelepen OutputUsing AIM Telepen Output, the imager reads symbols with start/stop pattern 1 and

Página 16

7 - 18UPC-A<Default All UPC-A Settings>UPC-AUPC-A Check DigitThis selection allows you to specify whether the check digit should be transmit-ted

Página 17 - Getting Started

7 - 19UPC-A AddendaThis selection adds 2 or 5 digits to the end of all scanned UPC-A data.Default = Off for both 2 Digit and 5 Digit Addenda.UPC-A Add

Página 18 - Imager Models

7 - 20UPC-A/EAN-13 with Extended Coupon CodeUse the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the

Página 19 - Imager Identification

7 - 21UPC-E0 ExpandUPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off.UPC-E0 Addenda RequiredWhen Required is scanned,

Página 20

7 - 22UPC-E0 Number SystemThe numeric system digit of a UPC symbol is normally transmitted at the begin-ning of the scanned data, but the unit can be

Página 21

7 - 23EAN/JAN-13<Default All EAN/JAN Settings>EAN/JAN-13EAN/JAN-13 Check DigitThis selection allows you to specify whether the check digit shoul

Página 22

7 - 24EAN/JAN-13 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.Default = Off for both 2 Digit and 5 Digit Addenda

Página 23 - Terminal

7 - 25ISBN TranslateWhen On is scanned, EAN-13 Bookland symbols are translated into their equiv-alent ISBN number format. Default = Off.EAN/JAN-8<D

Página 24 - Laptop Direct Connect

viPostal Codes ...7-38Intelligent Mail Barcode ...7-38ID

Página 25 - USB Connection

7 - 26EAN/JAN-8 AddendaThis selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.Default = Off for both 2 Digit and 5 Digit Addenda.E

Página 26 - ). The

7 - 27MSI<Default All MSI Settings>MSIMSI Check CharacterDifferent types of check characters are used with MSI barcodes. You can program the im

Página 27 - RS-232 Serial Port Connection

7 - 28MSI Message LengthScan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional informati

Página 28 - Default = P1

7 - 29GS1 DataBar Omnidirectional< Default All GS1 DataBar Omnidirectional Settings >GS1 DataBar OmnidirectionalGS1 DataBar Limited< Default

Página 29 - Wand Emulation Connection

7 - 30GS1 DataBar ExpandedGS1 DataBar Expanded Message LengthScan the barcodes below to change the message length. Refer to Message Length Descriptio

Página 30

7 - 31PosiCode<Default All PosiCode Settings>PosiCode A and BYou have to have PosiCode A and B on to read any of the PosiCode symbolo-gies.PosiC

Página 31 - Reading Techniques

7 - 32Trioptic CodeNote: If you are going to scan Code 32 Pharmaceutical codes (page 7-7), Trioptic Code must be off.Trioptic Code is used for labelin

Página 32

7 - 33Code 16K<Default All Code 16K Settings>Code 16KCode 16K Message LengthScan the barcodes below to change the message length. Refer to Mess

Página 33 - Terminal Interfaces

7 - 34Code 49<Default All Code 49 Settings>Code 49Code 49 Message LengthScan the barcodes below to change the message length. Refer to Message

Página 34 - Supported Terminals

7 - 35PDF417< Default All PDF417 Settings >PDF417PDF417 Message LengthScan the barcodes below to change the message length. Refer to Message Le

Página 35

viiOCR Templates ... 9-3Creating an OCR Template... 9-3Stringin

Página 36 - Keyboard Country

7 - 36MicroPDF417< Default All MicroPDF417 Settings >MicroPDF417MicroPDF417 Message LengthScan the barcodes below to change the message length.

Página 37 - Keyboard Country (continued)

7 - 37UPC/EAN VersionScan the UPC/EAN Version On barcode to decode GS1 Composite symbols that have a UPC or EAN linear component. (This does not affe

Página 38 - Regular

7 - 38Default = GS1 Emulation Off.TCIF Linked Code 39 (TLC39)This code is a composite code since it has a Code 39 linear component and a MicroPDF417 s

Página 39 - Keyboard Modifiers

7 - 39ID-tag (UPU 4-State)Note: You may enable the ID-tag (UPU 4-State) if you have firmware with a base number of 31205480. Refer to the Show Softw

Página 40 - Default = Off

7 - 40Planet CodePlanet Code Check DigitThis selection allows you to specify whether the check digit should be transmit-ted at the end of the scanned

Página 41

7 - 41British PostCanadian PostKix (Netherlands) PostNote: Kix code can misread when scanned sideways or upside down. Use Working Orientation, page 3

Página 42 - Default = 1

7 - 42Australian Post InterpretationThis option controls what interpretation is applied to customer fields in Austra-lian 4-State symbols. Bar Output

Página 43 - Default = None

7 - 43Japanese PostChina Post<Default All China Post Settings>China PostChina Post Message LengthScan the barcodes below to change the message l

Página 44 - RS-232 Handshaking

7 - 44Korea Post<Default All Korea Post Settings>Korea PostKorea Post Message LengthScan the barcodes below to change the message length. Refer

Página 45

7 - 45QR Code< Default All QR Code Settings >QR CodeThis selection applies to both QR Code and Micro QR Code. Note: The default applies to firm

Página 46 - Default = 50ms

viiiChapter 12 - Serial Programming CommandsConventions...12-1Menu Command Syntax ...

Página 47 - Default = Black High

7 - 46Data Matrix< Default All Data Matrix Settings >Data MatrixData Matrix Message LengthScan the barcodes below to change the message length.

Página 48 - Default = Idle

7 - 47MaxiCode< Default All MaxiCode Settings >MaxiCodeMaxiCode Message LengthScan the barcodes below to change the message length. Refer to M

Página 49

7 - 48Aztec Code< Default All Aztec Code Settings >Aztec CodeAztec Code Message LengthScan the barcodes below to change the message length. Ref

Página 50 - Default = Normal

7 - 49Chinese Sensible (Han Xin) Code< Default All Han Xin Settings >Han Xin CodeHan Xin Code Message LengthScan the barcodes below to change th

Página 52 - Trigger Modes

8 - 18Imaging CommandsThe image scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands al

Página 53 - Low Power Time-Out Timer

8 - 2Step 1 - Take a Picture Using IMGSNPImage Snap - IMGSNPAn image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP)

Página 54 - Scan Stand Mode

8 - 3L - LED StateDetermines if the LEDs should be on or off, and when. Ambient illumination (0L) is preferred for taking pictures of color documents

Página 55 - Presentation Mode

8 - 4G - GainGain is used in Manual Style only (2P). Like a volume control, the gain modifier boosts the signal and multiplies the pixel value. As yo

Página 56

8 - 5% - Target Set Point PercentageSets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixe

Página 57 - Default = 5,000

ixAppendix A - Reference ChartsSymbology Chart...A-1ASCII Conversion Chart (Code Page 1252) ...

Página 58 - LED Power Level

8 - 6IMGSHP ModifiersA - Infinity FilterEnhances pictures taken from very long distances (greater than 10 feet or 3m). The Infinity Filter should not

Página 59 - Illumination Lights

8 - 7E - Edge SharpenAn edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the

Página 60 - Aimer Delay

8 - 8H - Histogram StretchIncreases the contrast of the transmitted image. Not available with some image formats. 0H No stretch (default)1H Histogr

Página 61 - Interlaced

8 - 9IF- Noise ReductionUsed to reduce the salt and pepper noise in an image.0if No salt and pepper noise reduction (default)1if Salt and pepper noise

Página 62

8 - 10J - JPEG Image QualitySets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger file

Página 63 - Preferred Symbology

8 - 11nB The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 480. (Default = all rows)Alternately, s

Página 64 - Preferred Symbology Off

8 - 12S - Pixel ShipPixel Ship sizes an image in proportion to its original size. It decimates the image by shipping only certain, regularly spaced p

Página 65 - Output Sequence Overview

8 - 13nU Apply document image filter using grayscale threshold n. Use lower numbers when the image contrast is lower. 1U will have a similar effect

Página 66 - Output Sequence Examples

8 - 14W - Histogram ShipA histogram gives a quick picture of the tonal range of an image, or key type. A low-key image has detail concentrated in the

Página 67

8 - 15To see this example, align the aimer with the signature area (not with the bar-code), then press the trigger. Send the following IMGBOX command

Página 69 - Default = 4

8 - 16B - Output Image Height This option is used to size the image vertically. If using this option, set the resolution (R) to zero.D - Pixel Dept

Página 70 - Default = Upright

8 - 17K - Gamma CorrectionGamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma corr

Página 71

8 - 18R - Resolution of Signature Capture AreaThe resolution is the number of pixels that the imager outputs per each minimum bar width. The higher t

Página 72

8 - 19X - Horizontal Barcode OffsetThe horizontal barcode offset allows you to offset the horizontal center of the signature capture area. Positive v

Página 74 - To Add a Prefix or Suffix:

9 - 19OCR ProgrammingUse this section to program the Imager for optical character recognition (OCR). The 2D imager reads 6 to 60 point OCR typeface.N

Página 75

9 - 2OCR-B On allows you to scan characters in the OCR-B font. The default set-ting allows you to scan any eight digit combination. If you have crea

Página 76 - Default = Enable

9 - 3SEMI FontSEMI Font On allows you to scan the SEMI font used in the semiconductor industry.All OCR Off turns off all OCR capability in the imager,

Página 77 - Prefix Scanned Data Suffix

9 - 4Template CharactersNote: OCR templates default to eight digits, no check character. To Add an OCR Template1. Turn on the OCR font you want to re

Página 78 - 1 2345STX HT CR LF

9 - 5Character Match SequencesThis method is used if you need a template that shows a specific character in a specific position. Put the character in

Página 79 - Intermessage Delay

1 - 11Getting StartedAbout This ManualThis User’s Guide provides installation and programming instructions for the 4000 Series imagers. Product speci

Página 80

9 - 6To create this template, you would enable the OCR-A font. Scan the Enter OCR Template symbol (page 9-13). Scan the d from the OCR Programming C

Página 81 - Data Formatting

9 - 7Reading Multi-Row OCRThe imager is capable of decoding multi-row OCR text. Note: Reading rows longer than sixteen characters is not recommended

Página 82 - Syntax = F3ssxx

9 - 8Example: You need to read any combination of seven digits, with a modulo 10 check character in the eighth position. The template would be:dddddd

Página 83 - Miscellaneous Commands

9 - 90123456789XAlso enter the OCR template:dddddddcEnable the OCR-A font, then scan the following string:6512351XThe imager performs the following ch

Página 84 - Syntax = ED

9 - 103-1-3-1 Weighted Modulo 10 Check CharacterStarting with the check character and working backward through the message, the imager applies a multi

Página 85 - Data Formatter

9 - 11Then scan the string below:0128454The reader performs the check character computation below:(0 x 1 + 1 x 2 + 2 x 1 + 8 x 2 + 4 x 1 + 5 x 2 + 4 x

Página 86 - Alternate Data Formats

9 - 124. Scan the symbol below to set up three templates to handle the ISBN number, the three digit price field, and the four digit price field.5. Fin

Página 87 - Secondary Interface

9 - 13OCR Template CodesNote: Reading more than three rows of OCR is not recommended. Contact the factory if you have an application that requires re

Página 89

10 - 110Interface KeysKeyboard Function RelationshipsThe following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships appl

Página 90

1 - 2Imager ModelsThe chart below lists the interfaces that can be used with your imager. Refer to Chapter 6 for programming information regarding se

Página 91

10 - 2The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of th

Página 92 - Secondary Trigger Mode

10 - 3Supported Interface KeysASCII HEXIBM AT/XT and PS/2 Compatibles, WYSE PC/ATSupported KeysIBM XTs and CompatiblesSupported KeysIBM, DDC, Memorex

Página 93 - Hands Free Time-Out

10 - 4Supported Interface Keys ASCIIHEXIBM, Memorex Telex (102)*Supported KeysMemorex Telex (88)**Supported KeysNUL 00 Reserved ReservedSOH 01 Enter E

Página 94

10 - 5Supported Interface KeysASCII HEXEsprit 200, 400ANSISupported KeysEsprit 200, 400ASCIISupported KeysEsprit 200, 400PCSupported KeysNUL 00 Reserv

Página 95 - Symbologies

10 - 6Supported Interface KeysASCII HEXApple Mac/iMac Supported KeysNUL 00 ReservedSOH 01 Enter/Numpad EnterSTX 02 CAPSETX 03 ALT makeEOT 04 ALT break

Página 96 - Message Length Description

11 - 111UtilitiesTo Add a Test Code I.D. Prefix to All SymbologiesThis selection allows you to turn on transmission of a Code I.D. before the decoded

Página 97 - Default = Don’t Transmit

11 - 2Show Scan Driver RevisionScan the barcode below to output the scan driver revision. The scan driver con-trols image capture.You may use the Sho

Página 98 - Stop Start StopStart

11 - 3Test MenuWhen you scan the Test Menu On code, then scan a programming code in this manual, the imager displays the content of a programming code

Página 99 - Trans mit

11 - 4You can exit Full Report mode by either typing the menu command, 2D_PQA0, if you are using Quick*View, or by scanning the following barcode:Note

Página 100 - Default = Off

11 - 5Scan DataScan Data allows you to scan barcodes and display the barcode data in a win-dow. Scan Data lets you send serial commands to the imager

Página 101 - Full ASCII

1 - 3Imager IdentificationCompliance Label locationItem Number, Serial Number and Revision Information location

Página 102 - Interleaved 2 of 5

11 - 6Quick*ViewQuick*View is a Microsoft Windows® program that displays decoded symbol messages and captures images (for instance, ID photographs) fr

Página 103 - Default = No Check Digit

12 - 112Serial Programming CommandsThe serial programming commands can be used in place of the programming barcodes. Both the serial commands and the

Página 104 - Code 93 Message Length

12 - 2Query CommandsSeveral special characters can be used to query the device about its settings.^ What is the default value for the setting(s).? Wha

Página 105 - Straight 2 of 5 Industrial

12 - 3Examples of Query CommandsIn the following examples, a bracketed notation [ ] depicts a non-displayable response.Example #1:What is the range

Página 106 - Straight 2 of 5 IATA

12 - 4Trigger CommandsYou can activate and deactivate the imager with serial trigger commands. First, the imager must be put in Manual/Serial Trigger

Página 107 - Matrix 2 of 5

12 - 5Program Keyboard Country*U.S.A.KBDCTY02-4BelgiumKBDCTY12-4BrazilKBDCTY162-4Canada (French)KBDCTY182-4Czech RepublicKBDCTY152-4DenmarkKBDCTY82-4F

Página 108 - Default = Two Check Digits

12 - 6Keyboard Style *RegularKBDSTY02-6Caps LockKBDSTY12-6Shift LockKBDSTY22-7Automatic Caps LockKBDSTY62-7Emulate ExternalKeyboardKBDSTY52-7Keyboard

Página 109 - Default

12 - 7Word Length: Data Bits, Stop Bits, and Parity7 Data, 1 Stop, Parity Even232WRD32-117 Data, 1 Stop, Parity None232WRD02-117 Data, 1 Stop, Parity

Página 110 - Code 128 Code Page

12 - 8Wand Emulation Transmission Rate10WNDSPD02-15*25WNDSPD12-1540WNDSPD22-1580WNDSPD32-15120WNDSPD42-15150WNDSPD52-15200WNDSPD62-15Wand Emulation Po

Página 111 - Default = AIM Telepen Output

12 - 9Good Read Delay*No DelayDLYGRD03-3Short Delay (500 ms)DLYGRD5003-3Medium Delay (1000 ms)DLYGRD10003-3Long Delay (1500 ms)DLYGRD15003-3User-Speci

Página 112 - Default = On

DisclaimerHoneywell International Inc. (“HII”) reserves the right to make changes in speci-fications and other information contained in this document

Página 113 - Default = Not Required

1 - 4Connecting the Imager with Keyboard WedgeNote: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.An im

Página 114

12 - 10LED Power LevelOffPWRLDC03-11Low (50%)PWRLDC503-11*High (100%)PWRLDC1003-11Illumination Lights*Lights OnSCNLED13-11Lights OffSCNLED03-11Imager

Página 115

12 - 11Preferred SymbologyOnPRFENA13-16*OffPRFENA03-16High Priority SymbologyPRFCOD##3-16Low Priority SymbologyPRFBLK##3-16Preferred Symbology Timeout

Página 116

12 - 12Suffix Add SuffixSUFBK2##4-4Clear One SuffixSUFCL24-4Clear All SuffixesSUFCA24-4Function Code Tran smi t*EnableRMVFNC04-4DisableRMVFNC14-4Inter

Página 117

12 - 13Secondary Code 39 Wand Emulation Wand Emulation Same Code Format2IFTYP646-2Wand Emulation Code 39 Format2IFTYP616-3Wand Emulation Multi BlockDe

Página 118

12 - 14Hands Free Time-OutRange 0 - 300,000 msTRGPTO######6-7Scan Stand Scan Stand Mode2IFTRG46-8Scan Stand SymbolFNC36-8Presentation Presentation Mod

Página 119

12 - 15Code 39 Check Char.*No Check Char.C39CK207-6Validate, But Don’t Tran smi tC39CK217-6Validate, and TransmitC39CK227-6Code 39 Message LengthMinim

Página 120

12 - 16Straight 2 of 5 IndustrialDefault All Straight 2 of 5 Industrial SettingsR25DFT7-11Straight 2 of 5 Industrial*OffR25ENA07-11OnR25ENA17-11Straig

Página 121 - MSI Check Character

12 - 17ISBT Concatenation*OffISBENA07-15OnISBENA17-15Code 128 Message LengthMinimum (0 - 80) *0128MIN##7-16Maximum (0 - 80) *80128MAX##7-16Code 128

Página 122 - Plessey Code

12 - 18UPC-A/EAN-13 with Extended Coupon Code*OffCPNENA07-20Allow ConcatenationCPNENA17-20Require ConcatenationCPNENA27-20UPC-E0 Default All UPC-ESett

Página 123 - GS1 DataBar Expanded

12 - 19EAN/JAN-13 2 Digit Addenda2 Digit Addenda OnE13AD217-24*2 Digit Addenda OffE13AD207-245 Digit Addenda OnE13AD517-24*5 Digit Addenda OffE13AD507

Página 124

1 - 5Connecting the Imager with USBNote: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.An imager can be

Página 125 - PosiCode

12 - 20MSI Check Character*Validate Type 10, but Don’t Tra nsm itMSICHK07-27Validate Type 10 and Tra nsm itMSICHK17-27MSI Message LengthMinimum (4 - 4

Página 126 - Trioptic Code must be off

12 - 21PosiCode OffPOSENA07-31*OnPOSENA17-31A and B OnPOSLIM07-31A and B and Limited A OnPOSLIM17-31*A and B and Limited B OnPOSLIM27-31PosiCode Msg.

Página 127 - Code 16K

12 - 22MicroPDF417 Default All Micro PDF417 SettingsMPDDFT7-36MicroPDF417 OnMPDENA17-36*OffMPDENA07-36MicroPDF417 Msg. LengthMinimum (1-366) *1MPDMIN7

Página 128 - Code 49 Message Length

12 - 23Planet Code Check DigitTran smi tPLNCKX17-40*Don’t TransmitPLNCKX07-40British Post OnBPOENA17-41*OffBPOENA07-41Canadian Post OnCANENA17-40*OffC

Página 129 - PDF417 Message Length

12 - 24Data Matrix Default All Data Matrix SettingsIDMDFT7-46Data Matrix *OnIDMENA17-46OffIDMENA07-46Data Matrix Msg. LengthMinimum (1-3116) *1IDMMIN7

Página 130 - GS1 Composite Codes

12 - 25Imaging Default CommandsDefault all Imaging Commands IMGDFT 8-1Image Snap Imaging Style - Decoding SNPSTY0 8-2*Imaging Style - Photo SNPSTY1 8-

Página 131 - GS1 Emulation

12 - 26Image Ship (continued)Sharpen Edges (0-23) IMGEDG## 8-7*File Format - JPEG IMGFMT6 8-7File Format - KIM IMGFMT0 8-7File Format - TIFF binary IM

Página 132 - Postal Codes

12 - 27Image Ship (continued)Image Crop - Top (0-480) *0 IMGWNT### 8-10Image Crop - Bottom (0-480) *479IMGWNB### 8-11Image Crop - Margin (0-238) *0IMG

Página 133 - Postnet Check Digit

12 - 28OCR Check CharacterOCR Mod. 10 Check Char. “OCRCHK0123456789”9-8OCR Mod. 36 Check Char. “OCRCHK0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ”9-8OCR User

Página 134 - Planet Code Check Digit

13 - 113Product Specifications4600g and 4600rParameter Specification4600g/4600r Dimensions (Typical):Height6.2 inches (15.7 cm)Length5.3 inches (13.5

Página 135 - Australian Post

1 - 6Connecting the Imager with RS-232 Serial PortNote: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.1

Página 136

13 - 24800iVibration Withstands 5G peak from 22 to 300 HzESD Tolerance 15 kV to any external surfaceParameter SpecificationDimensions (Typical):Height

Página 137 - China Post Message Length

13 - 3Standard Cable PinoutsKeyboard Wedge10 Pin RJ41 Modular Plugconnects to the imager handle1 2Cord shield3 Prog 14 Supply ground5 Terminal clock6

Página 138 - Korea Post Message Length

13 - 4Wand Emulation10 Pin Modular Plugconnects to the imager handle12Cord shield3 Tied to 5 Volt power 4 Supply ground56 Barcode data output7 5 Volt

Página 139 - QR Code Message Length

13 - 5Serial Output 10 Pin RJ41 Modular Plugconnects to the imager handle12 Cord shield3 Tied to 5 Volt power4 Supply ground5 Receive data - Serial da

Página 140 - Data Matrix

13 - 6USB10 Pin Modular Plugconnects to the imager handle12 Data +3 Tied to 5 volt power4 Supply ground567 5 volt power connection8910 Data -

Página 141 - MaxiCode

14 - 114MaintenanceRepairsRepairs and/or upgrades are not to be performed on this product. These ser-vices are to be performed only by an authorized

Página 142 - Aztec Code

14 - 2Replacing the Interface CableThe standard interface cable is attached to the imager with an 10-pin modular connector. When properly seated, the

Página 143 - Han Xin Code Message Length

14 - 3To Replace the 4600rp Interface Cable:1. Turn the power to the host system OFF.2. Disconnect the imager’s cable from the terminal or computer.3.

Página 144

14 - 48. Screw the cord lock back in place over the cord.TroubleshootingThe imager automatically performs self-tests whenever you turn it on. If your

Página 145 - Imaging Commands

14 - 51. Scan the sample barcodes in the back of this manual. If the imager reads the sample barcodes, check that your barcode is readable.Verify tha

Página 146 - (default)

1 - 71. Turn off power to the computer.2. Disconnect the existing serial cable from the computer.3. Connect the appropriate interface cable to the ima

Página 148

15 - 115Customer SupportTechnical AssistanceIf you need assistance installing or troubleshooting your device, please call your distributor or the near

Página 149 - Image Ship - IMGSHP

15 - 2Product Service and RepairHoneywell International Inc. provides service for all its products through service centers throughout the world. To o

Página 150 - (default)

15 - 3Limited WarrantyHoneywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to

Página 151

15 - 4by this warranty. This includes but is not limited to: cables, power supplies, cra-dles, and docking stations. HII extends these warranties only

Página 152

A - 1AReference ChartsSymbology ChartSymbology AIM IDPossible AIM ID Modifiers (m)Code ID (hex)All Symbologies (0x99)Australian Post ]X0 A (0x41)Azte

Página 153

A - 2Intelligent Mail Barcode ]X0 M (0x4D)Interleaved 2 of 5]Im0, 1, 3 e (0x65)Japanese Post ]X0 J (0x4A)KIX (Netherlands) Post ]X0 K (0x4B)Korea

Página 154

A - 3Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier charact

Página 155

A - 4ASCII Conversion Chart (Code Page 1252)Note:This table applies to U.S. style keyboards. Certain characters may differ depending on your Country

Página 156 - (default)

A - 5Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char128 80€€160 A0 192 C0 À 224 E0 à129 81 161 A1 ¡ 193 C1 Á 225 E1 á130 82 ‚ 162 A2 ¢ 194 C2 Â 22

Página 157

1 - 8Programming the Interface - Plug and PlayPlug and Play barcodes provide instant imager set up for commonly used inter-faces.Note: After you scan

Página 158

A - 6Code Page Mapping of Printed BarcodesCode pages define the mapping of character codes to characters. If the data received does not display with

Página 159 - IMGBOX Modifiers

Sample SymbolsUPC-A0 123456 7890Interleaved 2 of 5Code 128EAN-13Code 39Codabar1234567890Code 1289 780330 290951BC321A13579BCode 93123456-9$Straigh

Página 160

Sample Symbols6543210ID-tag (UPU 4-State)J18CUSA8E6N062315014880TPDF417PostnetCode 49Car RegistrationZip Code1234567890Data MatrixQR CodeTest S ymbo l

Página 161

Sample SymbolsAztecMaxiCodeMicro PDF417Package LabelTest MessageTest MessageOCR-B with Modulo 10 check characterOCR-A with Modulo 36 check character

Página 162

OCR Programming Chartaedgchtlr

Página 163

OCR Programming ChartTDAOSaveDiscard

Página 164

Programming ChartACBFED1023

Página 165 - OCR Programming

Programming ChartNote: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or dig

Página 166 - MICR E13 B Font

Honeywell700 Visions DriveP.O. Box 208Skaneateles Falls, NY 13153-020846gr-48i-UG Rev F2/09

Página 167 - OCR Templates

1 - 9USB ConnectionIBM SurePosScan one of the following “Plug and Play” codes to program the imager for IBM SurePos (USB handheld imager) or IBM SureP

Página 168 - 37680981

1 - 10USB PC or Macintosh® KeyboardScan one of the following codes to program the imager for USB PC Keyboard or USB Macintosh Keyboard. Scanning thes

Página 169 - 551ABC983

1 - 11CTS/RTS EmulationACK/NAK ModeRS-232 Serial Port ConnectionAll communication parameters between the imager and terminal must match for correct da

Página 170 - OCR User-Defined Variables

1 - 12Serial Wedge Data Transmission PortUsing the following barcodes, set the port to which you want the scanned data to transmit. Port 1 correspond

Página 171 - OCR Check Character

1 - 13Each of the previous barcodes also programs the following suffixes for each symbology:.The IBM 4683 Port 9B HHBCR-2 Interface barcode also prog

Página 172 - 01234569

and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a resident

Página 173 - 6512351X

1 - 1425 inches per second, Output Polarity to black high, and Idle State to high. (If you want to change the terminal ID only, without changing any

Página 174 - 01234565

1 - 15Reading TechniquesThe imager has a view finder that projects a bright red or green aiming beam that corresponds to the imager’s horizontal field

Página 176

2 - 12Terminal InterfacesTerminal IDIf your interface is not covered by a Plug and Play barcode from Chapter 1, then refer to Supported Terminals on p

Página 177 - OCR Template Codes

2 - 2Supported Terminals Note: See "Imager Models" on page 1-2 to determine which interfaces apply to your imager.Terminal Model(s)Terminal

Página 178

2 - 3* Default for 4600g/4600r/4600rp/4800iXX 05XX models. It is best to use the Plug andPlay barcodes, beginning on page 1-9, to program these inter

Página 179 - Interface Keys

2 - 4Keyboard CountryScan the appropriate country code below to program the keyboard for your country. As a general rule, the following characters are

Página 180

2 - 5Keyboard Country (continued)Latin AmericaNorwayPolandPortugalRomaniaRussiaSCSSlovakiaItalyNetherlands (Dutch)SpainSwedenSwitzerland (German)

Página 181 - Supported Interface Keys

2 - 6Keyboard Country (continued)Please refer to the Honeywell website (www.honeywell.com/aidc) for complete keyboard country support information and

Página 182

2 - 7Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards).Automatic Caps Lock is used if you change the Caps

Página 183

Honeywell International Inc. shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE

Página 184

2 - 8support all keyboard country codes. New users should use the Windows mode. Refer to Keyboard Function Relationships, page 10-1 for CTRL+ ASCII

Página 185 - Utilities

2 - 9Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default =

Página 186 - Show Data Format

2 - 10RS-232 Baud RateBaud Rate sends the data from the imager to the terminal at the specified rate. The host terminal must be set for the same baud

Página 187 - Test Menu

2 - 11Parity provides a means of checking character bit patterns for validity.Default = None.RS-232 Receiver Time-OutThe unit stays awake to receive d

Página 188 - Visual Xpress Introduction

2 - 12receiver time-out by scanning the barcode below, then scanning digits from the inside back cover of this manual, then scanning Save. The range

Página 189 - Configure

2 - 13In Wand Emulation mode, the imager decodes the barcode then sends data in the same format as a wand imager. The Code 39 Format converts all sym

Página 190 - Quick*View

2 - 14Delay Between BlocksThis sets the delay time between data blocks. Default = 50ms.Overall ChecksumWhen this option is turned on, a computed chec

Página 191 - Serial Programming Commands

2 - 15Wand Emulation Transmission RateThe Transmission Rate is limited by the terminal’s ability to receive data without dropping characters. Default

Página 192 - Query Commands

2 - 16Wand Emulation IdleThe idle describes the state of the imager when no data is being transmitted. When in Wand Emulation mode, you must set the

Página 193 - Examples of Query Commands

3 - 13OutputGood Read IndicatorsBeeper – Good ReadThe beeper may be programmed On or Off in response to a good read. Turning this option off, only tu

Página 194 - # Indicates a

South Korea (4600r only) MIC Class A EMC requirements.Mexico Conforms to NOM-019.InternationalEye Safety Statement: LEDThis device has been tested i

Página 195

3 - 2Beeper Pitch – Good ReadThe beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium.Beeper

Página 196

3 - 3LED flashes are in sync with one another. To change the number of beeps, scan the barcodebarcode below and then scan a digit (1-9) barcode and t

Página 197

3 - 4Trigger ModesManual/Serial TriggerYou can activate the imager either by pressing the trigger, or using a serial trig-ger command (see Trigger Com

Página 198

3 - 5Low Power Time-Out TimerScan the Low Power Time-Out barcode to change the time-out duration (in seconds). Then scan the time-out duration (from

Página 199

3 - 6Scan Stand ModeWhen a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol (see below). When a different code is

Página 200

3 - 7Presentation ModeThis programs the imager to work in Presentation mode. The LEDs are either off or at the lowest power for ambient conditions un

Página 201

3 - 8Presentation SensitivityPresentation Sensitivity is a numeric range that increases or decreases the imager's reaction time to barcode presen

Página 202

3 - 9Image Snap and ShipImage Snap and Ship tells the imager to take a picture (rather than read a bar-code) when the trigger is pressed. Once the pi

Página 203

3 - 10Reread Delay only works when in Presentation Mode or Streaming Presentation™ Mode (page 3-8).User-Specified Reread DelayIf you want to set your

Página 204

3 - 11If you have an aimer delay programmed (see Aimer Delay on page 3-12), the aimer will be at 100% power during the delay, regardless of the LED Po

Página 206

3 - 12Imager Time-OutImager Time-Out powers down the imager after the unit has been idle for the specified time. To prevent the imager from powering

Página 207

3 - 13Aimer ModeThis feature allows you to turn the aimer on and off. When the Interlaced bar-code is scanned, the aimer is interlaced with the illum

Página 208

3 - 14imager’s field of view. The following diagram illustrates the default top, bottom, left, and right pixel positions, measured from the top and t

Página 209

3 - 15Decode Search ModeThere are three selectable decode (scanning) modes:Full Omnidirectional - Searches for barcode features beginning at the cente

Página 210

3 - 16Preferred Symbology classifies each symbology as high priority, low priority, or as an unspecified type. When a low priority symbology is prese

Página 211

3 - 17Preferred Symbology Time-outOnce you have enabled Preferred Symbology and entered the high and low pri-ority symbologies, you must set the time-

Página 212

3 - 18to apply the output sequence format. Locate the Hex value for that symbol-ogy and scan the 2 digit hex value from the Programming Chart (inside

Página 213

3 - 19SEQBLK sequence editor start command62 code identifier for Code 399999 code length that must match for Code 39, 9999 = all lengths41 start chara

Página 214

3 - 20Output Sequence Editor Require Output SequenceWhen an output sequence is Required, all output data must conform to an edited sequence or the i

Página 215

3 - 21new symbols as long as the trigger is pulled. When this programming selection is turned Off, the Imager will only read the symbol closest to th

Página 216

iChapter 1 - Getting StartedAbout This Manual ... 1-1Unpacking the Imager ...

Página 217

3 - 22Video ReverseVideo Reverse is used to allow the imager to read barcodes that are inverted. The Off barcode below is an example of this type of

Página 218

3 - 23* UprightRotate Code Clockwise 90°(Rotate Imager Counterclockwise)Upside DownRotate Code Counterclockwise 90°(Rotate Imager Clockwise)

Página 220 - Parameter Specification

4 - 14Data EditingPrefix/Suffix OverviewWhen a barcode is scanned, additional information is sent to the host computer along with the barcode data. T

Página 221 - Standard Cable Pinouts

4 - 2To Add a Prefix or Suffix:Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-4).Step 2. Determine the 2 digit Hex value from the Symbology

Página 222 - Wand Emulation

4 - 3To Clear One or All Prefixes or Suffixes:You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbol-ogy. When you Clea

Página 223 - Serial Output

4 - 4Prefix SelectionsSuffix SelectionsFunction Code TransmitWhen this selection is enabled and function codes are contained within the scanned data,

Página 224

4 - 5Intercharacter, Interfunction, and Intermessage DelaysSome terminals drop information (characters) if data comes through too quickly. Interchara

Página 225 - Maintenance

4 - 6Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversio

Página 226 - Replacing the Interface Cable

4 - 7Intermessage DelayAn intermessage delay of up to 495 milliseconds (in 5 ms steps) may be placed between each scan transmission. Scan the Interme

Página 227 - Cord lock

iiKeyboard Modifiers...2-7RS-232 Baud Rate...2-10RS-232

Página 229

5 - 15Data FormattingData Format Editor IntroductionYou may use the Data Format Editor to change the imager’s output. For exam-ple, you can use the D

Página 230

5 - 2Step 4. Code I.D.In the Symbology Chart (page A-1), find the symbology to which you want to apply the data format. Locate the Hex value for that

Página 231 - Customer Support

5 - 3F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi-tion. Syntax = F4xxnn (xx stands for the hex value for an ASCII

Página 232 - Product Service and Repair

5 - 4ters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2.E5 Terminates character replacement. Syntax = E5.FE C

Página 233 - Limited Warranty

5 - 5Data Format EditorData FormatterWhen Data Formatter is turned off, the barcode data is output to the host as read (including prefixes and suffixe

Página 234

5 - 6Alternate Data FormatsAlternate formats allow you “single shot” capability to scan one barcode using a different data format than your primary fo

Página 235 - Reference Charts

6 - 16Secondary InterfaceBy switching secondary interface cables, the imager can, for example, commu-nicate with a portable data terminal (secondary i

Página 236

6 - 2You can temporarily disable the secondary interface, but still retain the second-ary interface settings in the imager’s memory by scanning the Di

Página 237 - Symbologies, 99) entry

6 - 3The Code 39 Format barcode below sets the terminal ID to 61, and the Same Code Format barcode sets the terminal ID to 64.Wand Emulation Multi Blo

Página 238

iiiReread Delay ... 3-9User-Specified Reread Delay... 3-10

Página 239

6 - 4Overall ChecksumWhen this option is turned on, a computed check character is added at the end of the entire message. The check character is the

Página 240

6 - 5Wand Emulation PolarityThe polarity can be sent as standard with black bars high, or reversed with white bars high. Default = Black High.Wand Em

Página 241

6 - 6Secondary Trigger ModeManual/Serial TriggerYou can activate the imager either by pressing the trigger, or using a serial trig-ger command (see Tr

Página 242

6 - 7Low Power Time-Out TimerScan the Low Power Time-Out barcode to change the time-out duration (in seconds). Then scan the time-out duration (from

Página 243

6 - 8Scan Stand ModeWhen a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol. (See Scan Stand Symbol that follows.

Página 244

7 - 17SymbologiesThis programming section contains the following menu selections. Refer to Chapter 12 for settings and defaults.• All Symbologies • I

Página 245

7 - 2All SymbologiesIf you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. If on the other hand, you

Página 246

7 - 3Codabar<Default All Codabar Settings>CodabarCodabar Start/Stop CharactersStart/Stop characters identify the leading and trailing ends of th

Página 247

7 - 4When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar barcodes printed with a check character, but will no

Página 248 - Honeywell

7 - 5Codabar Message LengthScan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional inform