INSTALLATION ADDENDUM
69-2576-01
Wiring Configuration
ADVANCED MODELS (HE150/HE250/HE300)
Fig. 1. Wiring H8908 to humidify only with a call for heat or fan.
Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent control to program humidity calls with heat,
cool, or on demand.
HE150 OR HE250
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
HE300
H8908
10
OFF ON
20
30
40
50
60
M29938A
POWER IN
G OR W
C
OR
AIR PROVING
DEVICE
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
1
1
2
3
3
2
HE300 USES A LINE CORD PLUG.
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
1
3
2
H8908
10
OFF ON
20
30
40
50
60
POWER IN
G OR W
C
AIR PROVING
DEVICE
1
2
3
OR
M29939A
FROM
HUMIDITY
CONTROL
HE150 OR HE250
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
HE300
POWER IN
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
1
1
HE300 USES A LINE CORD PLUG.
1
POWER IN
FROM
HUMIDITY
CONTROL
1
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - Wiring Configuration

INSTALLATION ADDENDUM69-2576-01Wiring ConfigurationADVANCED MODELS (HE150/HE250/HE300)Fig. 1. Wiring H8908 to humidify only with a call for heat or fa

Página 2 - WIRING CONFIGURATION

WIRING CONFIGURATION69-2576—01 2Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand).Fig. 4. Wiring to force fan on

Página 3 - BASIC MODELS (HE100/HE200)

WIRING CONFIGURATION3 69-2576—01BASIC MODELS (HE100/HE200)Fig. 5. Wiring H8908 with fan interlock.Fig. 6. Wiring H8908 with 2-speed fan motor.H890812H

Página 4 - Printed in U.S.A

WIRING CONFIGURATIONAutomation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422Honeywell Limited-Hone