INSTALLATION INSTRUCTIONS
62-0332-03
E4436
C7400S Enthalpy Sylk Bus Sensor
PRODUCT DESCRIPTION
The C7400S Sylk Bus sensor is a combination temperature
and humidity sensor, which is intended to be used in
commercial roof top units for sensing air. The sensor is
powered by and communicates on the Sylk Bus. The C7400S
communicates temperature and humidity separately digitally
on the Sylk Bus Communication Protocol.
A separate controller such as the JADE™ Economizer
System (Model W7220) provides power and communications
on the Sylk Bus for the C7400S Sylk Bus sensor.
SPECIFICATIONS
Electrical
Supply Voltage: 7 to 21 Vdc
Power Consumption: 5 mA
Output Rating: 75 ohm load switched at 9600 Baud
Wiring: Sylk Bus: 2-wire (18 to 22 AWG)
Environmental
Operating Temperature range: -40 to 150 °F (-40 to 65 °C)
Storage Temperature range: -40 to 150 °F (-40 to 65 °C)
Shipping Temperature range: -40 to 150 °F (-40 to 65 °C)
Operating Relative Humidity range: 5% to 95% RH non-
condensing
Temperature and Humidity, C7400S:
Temperature sensing range: -40 to 150 °F (-40 to 65 °C)
Humidity sensing range: 0 to 100% RH with 5% accuracy.
Dimensions (See Fig. 1):
Height: 0.8 inches (20.5 mm)
Width: 2.17 inches (55 mm)
Length: 4.25 inches (108 mm)
Weight: 0.58 lb. (0.265 kg)
Listing Agency Approvals:
EN61000-6-3,EN61000-3-2;EN61000-3-3;EN61000-6-1;
EN60730-1 Annex H.23 (emissions)
Annex H.26 (immunity)
CE Mark FOR EU
Fig. 1. Dimensions in inches and (mm) showing mounting
holes.
M32331
4-1/4 (108)
2-1/64 (55)
51/64 (21)
2-3/4 (70)
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - SPECIFICATIONS

INSTALLATION INSTRUCTIONS62-0332-03E4436C7400S Enthalpy Sylk Bus SensorPRODUCT DESCRIPTIONThe C7400S Sylk Bus sensor is a combination temperature and

Página 2 - MOUNTING

C7400S ENTHALPY SYLK BUS SENSOR62-0332—03 2BEFORE INSTALLATIONReview the “Specifications” on page 1 before installing the sensor.When Installing This

Página 3 - TROUBLESHOOTING

C7400S ENTHALPY SYLK BUS SENSOR3 62-0332—03WIRINGAll wiring must comply with applicable electrical codes and ordinances, or as specified on installati

Página 4 - Printed in U.S.A

C7400S ENTHALPY SYLK BUS SENSORAutomation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden Valley, MN 55422customer.ho

Comentários a estes Manuais

Sem comentários