Honeywell MK2430 Stratos Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Leitores de códigos de barras Honeywell MK2430 Stratos. Honeywell MK2430 Stratos Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
MS2420 / MS2430
Bar Code Scanner / Diva Scale
Installation and User’s Guide
Vista de página 0
1 2 3 4 5 6 ... 91 92

Resumo do Conteúdo

Página 1 - MS2420 / MS2430

MS2420 / MS2430 Bar Code Scanner / Diva Scale Installation and User’s Guide

Página 2 - Trademarks

6 General Precautions The following are some general precautions to remember when handling your MS2420/MS2430 series scanner. Do not turn the u

Página 3 - Table of Contents

7 Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Horizontal Depth of Field: 0 mm – 100 mm (0"- 4

Página 4

8 Electrical Voltage Supply: 4A @ +5V / 1.5A @ +12V Power: Operating: 11.9 Watts Standby: 3.25 Watts Current: Operating: 1.7A @ 5.2V / 0.2A @

Página 5 - Introduction

9 Base Model Characteristics MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Components* Figure 6. Components* *MS2420 shown

Página 6 - Optional Accessories

10 MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Components Item No. Description of Item in Figure 7 1 Scale Zero Button (see page 47) 2 Am

Página 7

11 MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale MS2420 Dimensions Figure 7. MS2420 Dimensions MS2430 Dimensions Figure 8. MS2430 Dimension

Página 8

12 MS2420/MS2430 Scanner / Mettler-Toledo DIVA Scale Connector Panel Figure 9. MS2420/MS2430 Connector Panel

Página 9 - Replacement Parts

13 MS2420/MS2430 Scanner/Diva Scale Caution and Serial Number Labels Figure 10. MS2420/MS2430 Label Locations (Top) and Examples (Bottom) Cauti

Página 11 - Design Specifications

15 Installation Quick Installation Outline The following is a quick preview of the steps required for first time installations. Each item is disc

Página 12 - Environmental

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen

Página 13 - Base Model Characteristics

16 Site Requirements Service Access When routing and installing the cable(s) and power supply, make sure you leave access that these components ma

Página 14

17 Unpacking the Unit 1. Make sure the shipping box is topside up before opening. 2. Remove the accessories box and check the box’s content for

Página 15 - MS2430 Dimensions

18 Unpacking the Unit MS2420/MS2430 Package Warning There is a protective film located on the topside platter surface, vertical scan windows outer s

Página 16 - Connector Panel

19 Installing the Unit in the Counter MS2420 Mounting Diagram Figure 16. MS2420 Mounting Diagram Specifications are subject to change without no

Página 17

20 MS2430 Mounting Diagram (Two Point Support) Figure 17. MS2430 Mounting Diagram, Two Point Support Specifications are subject to change withou

Página 18

21 MS2430 Mounting Diagram (Three Point Support) Figure 18. MS2430 Mounting Diagram, Three Point Support Specifications are subject to change wi

Página 19 - Installation

22 Cable Installation (Interface Specific) RS232 The following steps describe how to properly install the cables for an RS232 application. The sc

Página 20 - Site Requirements

23 Cable Installation (Interface Specific) RS232 9. Turn on the host system. 10. Scan the Recall Defaults bar code. Note: The Recall Defaults bar

Página 21 - Unpacking the Unit

24 Cable Installation (Interface Specific) Full Speed USB The following steps describe how to properly install the cables for a Full Speed USB appli

Página 22

25 Cable Installation (Interface Specific) Full Speed USB 9. Turn on the host system. 10. Configure the scanner to match the host system’s USB para

Página 23 - MS2420 Mounting Diagram

iii Table of Contents Introduction Manual Scope ...

Página 24

26 Cable Installation (Interface Specific) Full Speed USB xx** Specifies international connection. See the Base Kit Components and Optional Acc

Página 25

27 Cable Installation (Interface Specific) RS485 The following steps describe how to properly install the cables for a RS485 application. The scan

Página 26

28 Cable Installation (Interface Specific) RS485 9. Turn on the host system. 10. Configure the scanner to match the host system’s RS485 parameters.

Página 27

29 Cable Installation (Secondary Honeywell Scanner) The following steps describe how to properly install the cables between a secondary Honeywell s

Página 28 - Full Speed USB

30 Cable Installation (Secondary Honeywell Scanner) † See Aux power notes on page 29 See power source caution statement on page 13 of this man

Página 29

31 EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a list of Check

Página 31

33 Scanner Operation Scan Zone Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subject to change

Página 32

34 Scan Zone Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subject to change without notice. Typ

Página 33

35 Wake Activation Area (Photocell LED Output) The MS2420/MS2430 scanner’s default power save mode† is Dual Action Power Save Mode #2 (see page 43).

Página 34

iv Scanner Operation Scan Zone ...

Página 35 - EAS Deactivation

36 Wake Activation Area Sensitivity (Photocell LED Output Range) Changing the Wake Area Sensitivity Level (Photocell LED Range Adjust) The MS2400 S

Página 36

37 Audible Indicators When in operation the MS2420/MS2430 provides audible feedback that indicates the status of the unit and the current scan. Ei

Página 37 - Scanner Operation

38 Visual Indicators Blue LED is located near the bottom corner of the vertical output window on the MS2420/MS2430. When the scanner is ON, the fla

Página 38 - Scan Zone

39 Failure Modes Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. The scanner will

Página 39 - (Photocell LED Output)

40 Diagnostic Indicator Display There is a two-digit error code display located under horizontal output window near the top of the platter (see fig

Página 40 - ³ 2 2 1 2 3 0

41 Diagnostic Indicator Display Error Code Description 09 COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the i

Página 41 - Audible Indicators

42 Diagnostic Indicator Display Error Code Description 26 LASER #3 (LEFT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical scanning sub

Página 42 - Visual Indicators

43 Power Save Modes The MS2420/MS2430 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional informat

Página 43 - Failure Modes

44 Beeper Options and Button Functions Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new

Página 44

45 Startup When the scanner first receives power, the blue LED will turn on and the scanner will beep once. The scanner is now ready to scan. Powe

Página 45 - Diagnostic Indicator Display

1 Introduction Manual Scope This guide provides information on the installation, setup, and operation of Honeywell’s MS2420 and MS2430 scanner/Div

Página 47 - Power Save Modes

47 Scale Operation Scale Zeroing After the unit has been officially calibrated (see page 48) the scale can be re-zeroed by pressing the scale-zeroi

Página 48 - The Multi-Function Button

48 Calibration The scanner/Diva scale must be calibrated if:  it is a first time installation  the scale cannot be re-zeroed  the calibration

Página 49 - Configuration Mode

49 Priming the Scale for Calibration (lbs. or kg) Prime the scale before starting either method of calibration. Note: Calibrate the scanner/Diva

Página 50

50 Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in a safe location. Note: It is t

Página 51 - Scale Operation

51 Scale Calibration Procedure (lbs. or kg) with Remote Display* 4. Reinstall the platter onto the scanner/Diva scale. Figure 44. Install Platte

Página 52 - Calibration

52 Scale Calibration Procedure (lbs. or kg) with Remote Display* 7. Go to Group 2 Step 6 (Calibration) of the Service Mode. Press the Tare (

Página 53 - Figure 39. Power Up Unit

53 Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when the remote scale display is not pre

Página 54

54 Bar Code Calibration Procedure without Remote Display* 3. Enter the scale program mode. Press the calibration button to engage the scale calib

Página 55 - Figure 44. Install Platter

55 ³ 9 9 6 0 4 4³ 9 9 6 0 4 2Bar Code Calibration Procedure without Remote Display* Unit Calibration (Pounds) For Kilogram weight units see instruct

Página 56

2 Base Kit Components Part # Description MS24x0-105Kz Scanner/Diva Scale x 2 MS2420; 399 mm (15.7") 3 MS2430; 508 mm (20.0") z D

Página 57

56 Bar Code Calibration Procedure without Remote Display* 6. Make sure there is no load on the scale platter. The blue LED will be used to indicat

Página 58

57 Bar Code Calibration Procedure without Remote Display* 10. Calibration process is now complete. The scanner will automatically restart, and beep

Página 59 - Pounds Calibration

58 Calibration Verification U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilograms see instructi

Página 60 - Figure 53

59 Calibration Verification Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Pounds see instruction

Página 61

60 Security Seal Installation Note: The certification of the weighing mechanism of the scale version of this scanner is subject to federal, state

Página 62 - Calibration Verification

61 Wire Security Seal (Seal Conversion Kit PN 46-00359)* 1. Temporarily remove the platter and place it in a safe location. 2. Install the calib

Página 64 - Security Seal Installation

63 Maintenance Horizontal Scan Window Replacement* Figure 61. Platter/Horizontal Scan Window Replacement * See replacement parts on page 4.

Página 65

64 Daily Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the horizontal or vertical output window

Página 66

65 Troubleshooting The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty

Página 67 - Maintenance

3 Optional Accessories Part # Description AC to DC Power Transformer - Regulated Output: +5V @ 4A +12V @ 0.8A 46-00980-R 120V United State

Página 68 - Daily Maintenance

66 Symptom Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the blue LED stays on). The s

Página 69 - Troubleshooting

67 Symptom Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to the host. The com port a

Página 71

69 Scanner and Cable Terminations Scanner Pinout Connections The MS2420/MS2430 scanner terminates to 10-pin modular jacks located on the bottom of

Página 72

70 Scanner Scale Pinout Connections There are four additional 10-pin modular jacks located on the bottom of the of the MS2420/MS2430 scanner models

Página 73 - Scanner Pinout Connections

71 Cable Connector Configurations RS232 Interface Cable, PN 57-57210x-N-3 Pin Function ** 9-Pin D-Type Connector 1 No Connect 2 RS232 Transmit

Página 74

72 Cable Connector Configurations Aux Port Configuration Cable*, PN 57-57008x-N-3 Pin Function** 9-Pin D-Type Connector 1 No Connect 2 Output

Página 75

73 Regulatory Compliance Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution

Página 76

74 EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not guaranteed for scanner

Página 77 - Regulatory Compliance

75 Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio c

Página 78 - European Standard

4 Optional Accessories Part # Description 46-00375 Remote Single Line Scale Display (lb.) (See Figure 1) 46-00376 Remote Single Line Scale Displ

Página 80

77 Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materi

Página 82

79 Patents For patent information, please refer to www.honeywellaidc.com/patents.

Página 84

81 Index A AC ... see power amber LED ... see indica

Página 85

82 power save ... 43, 44 protocols ...

Página 86

83 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nea

Página 87 - Customer Support

84 Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To

Página 89

5 Replacement Parts Part # Description Caution Window types (Diamonex and Sapphire) are not interchangeable due to laser safety and/or scanner pe

Página 92

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-05310 Rev E 4/11

Comentários a estes Manuais

Sem comentários